A certificate of analysis is only useful if you know which lines to read. This guide covers the four sections that matter, why the test method matters as much as the result, how batch traceability works, and the five-minute check we run before accepting a shipment.

A certificate of analysis is one of the few documents in a chemical transaction that a buyer can use to challenge a shipment. It is also, in most cases, read far too quickly: a glance at the assay figure, a check that the batch number matches the delivery note, and the file is closed. That is how non-conforming material gets accepted.

What follows is how we read a CoA when one arrives from a supplier, and how we build one when material leaves our own warehouse. It is written for purchasing and quality staff working with commodity and specialty chemicals, and it stays deliberately clear of instrument-level detail. The aim is a document check that anyone on the receiving side can complete in a few minutes.

Prepared by the JBSR Technical Sales team · Reviewed by the Quality & Compliance team · Updated 13 November 2026

What a CoA Is, and What It Is Not

A CoA records the results obtained on a specific batch, tested against an agreed specification. It is not a certificate of conformity, it is not a regulatory approval, and on its own it does not prove that the material inside a drum is the material described on the page.

The distinction is not academic. A supplier can issue an entirely genuine CoA for a batch produced months earlier, repacked since, and still hand you the original document. The certificate is accurate about what was tested, when it was tested and which sample was drawn. Every one of those qualifiers can drift away from the container standing in your goods-in area.

A useful way to put it: a CoA answers “what was in the sample?” It does not answer “what is in this container now?” Sampling, sealing and traceability are what connect the two, and none of them appear on the certificate.

This is why experienced buyers treat a CoA as one input among several, alongside the safety data sheet, the packing list, the seal numbers and, where the risk justifies it, a third-party inspection or an independent retest on arrival.

The Four Sections Worth Reading First

Most certificates follow the same skeleton: identification, specification and results, methods, and authorisation. Read them out of order, starting with identification, because a document with the wrong batch number is not worth analysing any further.

Section

What to check

Why it matters

Batch or lot number

Character-for-character match with the drum label, delivery note and packing list

A single differing character breaks traceability, and repacked material often loses this link entirely

Manufacture date and retest or expiry date

Both present, both consistent with the stated shelf life

Some products degrade, others stay stable while the inhibitor is consumed. An undated certificate cannot be tied to a shipment

Specification against result

Every result inside the stated limit, every unit matching

“99.5 min” and “99.5 max” are opposite requirements, and decimal separators differ between regions

Method and authorisation

A method named for each parameter, plus a signature and date

A result without a method cannot be reproduced or disputed on technical grounds

If any of those four is missing, the certificate is incomplete no matter how good the numbers look. A document that reports excellent results but omits the batch number is not a stronger CoA than one that reports mediocre results with full traceability — it is a weaker one.

The Test Method Matters as Much as the Result

Two certificates can both state 99.7% purity for the same product and mean different things. Purity by gas chromatography, purity by titration, and purity calculated by difference after subtracting water and volatiles are three separate measurements, each with its own bias and its own uncertainty. Comparing them as if they were interchangeable is one of the most common sources of dispute between buyer and supplier.

Glass burette and glassware arranged on a laboratory bench

Volumetric titration remains the reference method for many assay determinations. The certificate should name the method beside the result, not only in a footnote.

Water content is the clearest illustration. A line reading “water: 0.1% max” tells you very little until you know how it was determined. Karl Fischer titration, loss on drying and gas chromatography can produce materially different figures on the same sample, and loss on drying in particular measures more than water. If the specification was written around one method and the certificate reports another, the comparison is not valid even when both numbers sit inside the limit.

Gas chromatograph instrument loaded with sample vials in a laboratory

Chromatographic purity depends on column, carrier gas, detector and integration settings. Two laboratories running the same nominal method can still report different values.

For the monomers and solvents we handle, this matters constantly. Acrylic acid is shipped with an inhibitor, commonly 4-methoxyphenol at around 200 ppm, and that inhibitor is a specification line of its own rather than part of the assay. Styrene carries 4-tert-butylcatechol at a much lower level. A buyer who reads only the purity figure will never notice inhibitor depletion, which is exactly the parameter that decides whether a drum is still usable after a long sea voyage.

Reading Tolerances Without Getting Fooled

Numeric conventions cause avoidable arguments. Four of them account for most of what we see:

  • Minimum and maximum reversed. “Assay 99.5% min” and “99.5% max” describe opposite materials, and the two are easy to transpose when a specification is copied between documents.

  • Decimal comma against decimal point. A European specification writing 99,5% means 99.5%, not 995 parts per million of something else. Mixed conventions inside one document are a warning sign about how it was prepared.

  • Units that look alike. One percent is 10,000 ppm, and mg/kg equals ppm for solids and liquids. A limit written as 0.05% and a result written as 400 mg/kg need a conversion before anyone can say whether the batch passes.

  • “Typical” presented as “guaranteed”. A typical value describes what a process usually produces. It is not a specification, and it cannot be used to reject a batch. Only a stated limit can.

There is a quieter version of the same problem: basis. A result expressed on a dry basis and a result expressed as received are not comparable, and neither is wrong. The certificate has to say which one it is using.

Traceability: From Reactor to Container

Traceability is what turns a certificate into evidence. It has three links, and all three have to hold: the reactor batch, the sample drawn from it, and the container that sample represents.

Chemical drums carrying batch labels stored in a warehouse

The batch identity on the drum label, not only on the document, is what links a certificate to the material actually received.

In practice, the weak link is usually the third. A top sample taken from an isotank after a long voyage is convenient but not automatically representative: temperature cycling during transit can leave a stratified layer, particularly with glycols and aqueous solutions. Composite sampling from top, middle and bottom, with the sample sealed and labelled at the point of drawing, is a materially stronger position if a dispute arises later.

Repacking is the other common break. Material transferred from an isotank into drums for a smaller order needs its own labels, its own seal numbers and a certificate that references the original batch rather than quietly issuing a new one. When a supplier cannot describe that chain in plain language, the documentation is usually thinner than it appears.

Where CoAs Fail in Practice

Four failure modes account for most of the documentation problems we are asked about:

  1. Values that never change. Identical figures across several batches and several months, with only the batch number updated. Real processes vary slightly run to run; perfect repetition suggests a template rather than a test.

  2. Retest dates presented as manufacture dates. The date moves forward when material is re-certified, and the age of the stock disappears from the document.

  3. Partial parameters. The specification lists eight lines, the certificate reports two, and the remaining six are treated as understood. They are not.

  4. No sampling statement. The certificate does not say when, where or by whom the sample was drawn, which makes the result impossible to defend if the receiving laboratory disagrees.

None of these requires bad faith. Most come from a supplier using the same template for years and never being asked a direct question about it.

A Five-Minute Pre-Shipment Check

Before accepting documents for a shipment, we run the same short sequence. It takes about five minutes and catches the majority of problems while they are still cheap to fix:

  • Batch number on the certificate matches the label, the packing list and the delivery note, character for character.

  • Manufacture date and retest or expiry date are present, and both are consistent with the shelf life quoted for the product.

  • Every parameter in the agreed specification appears on the certificate, and every result is inside its limit after unit conversion.

  • A method is named for each parameter, and the method matches the one the specification was written against.

  • The certificate is signed, dated, and carries the name or stamp of the issuing quality function.

  • Inhibitor content, where applicable, is reported and still above the minimum for the intended transit time.

If all six pass, the documents are in order. If one fails, the question to ask is specific: not “can you send a CoA”, but “which batch was this drawn from, on what date, and by which method was the water content determined”. Suppliers answer specific questions far more reliably than general ones.

Verifying a Supplier You Have Not Used Before

Certification is often misunderstood in this context. ISO 9001:2015 confirms that a quality management system exists and is audited; it says nothing about whether the laboratory producing your certificate is competent. ISO/IEC 17025:2017 is the relevant standard for testing and calibration competence, and it is scoped: an accredited laboratory is accredited for the specific tests listed in its scope, not for everything it performs.

So the practical request is not “send us your certificates” but “send us the accreditation certificate and the scope covering these tests”. A supplier who can produce that document quickly is usually also able to answer method questions. ISO 17034 covers producers of reference materials, which matters when a result depends on a calibration standard rather than on an absolute method.

Two further checks are worth the effort. Ask for the safety data sheet in the language and GHS revision required at the destination, since classification and content differ between jurisdictions. And if the material enters the EU, confirm the REACH registration status of the substance and the correct classification under CLP, because a certificate that is technically sound can still leave a shipment non-compliant.

Common Questions

Is a CoA the same as an SDS?

No. The safety data sheet describes hazards, handling, transport classification and emergency measures for a substance or mixture. The certificate of analysis reports measured results for a specific batch. A shipment normally needs both, and one does not substitute for the other.

Can I accept a certificate issued before shipment?

Yes, provided the date, the batch and the packaging all still correspond to what arrives, and the material is inside its retest window on the date of receipt. For inhibited monomers, add the transit time to the calculation: a certificate that is valid on the day of loading can be close to the limit on the day of discharge.

The result is inside specification but very close to the limit. Is that a problem?

It depends on measurement uncertainty and on what you are doing with the material. A result of 99.51% against a 99.5% minimum sits inside the limit but within the uncertainty of many methods, which means the batch could equally be marginally out. For critical applications, ask for the uncertainty or request a retest rather than debating the third decimal place.

Why do two laboratories report different purity for the same sample?

Different methods, different calibration standards, different integration settings and, occasionally, different sampling. Where the discrepancy is small and both results are inside specification, the usual explanation is method bias rather than a quality problem. Where the gap is large, the sampling chain deserves more attention than the instruments.

How We Handle Documentation

Our practice rests on three rules, and they are the reason we can answer the questions above without asking for time to check.

First, every shipment leaves with a batch-specific certificate that names the method beside each result, not in a footnote. Second, the lot number on the certificate is the same lot number that appears on the drum, the packing list and the commercial invoice, so the chain can be followed without guesswork. Third, if a customer asks for a parameter we do not routinely report, we say so and offer an independent test rather than quietly omitting the line.

If you are reviewing a specification, or comparing two suppliers on documentation rather than price, send us the parameters that matter to your process. We will tell you what we can certify directly and what needs a third-party laboratory, and if a requirement cannot be met we would rather say so before the order than after it.

References and Further Reading

  • ISO 9001:2015 — Quality management systems — Requirements. International Organization for Standardization.

  • ISO/IEC 17025:2017 — General requirements for the competence of testing and calibration laboratories. ISO/IEC.

  • ISO 17034:2016 — General requirements for the competence of reference material producers. ISO.

  • ASTM E300 — Standard Practice for Sampling Industrial Chemicals. ASTM International.

  • ASTM E203 — Standard Test Method for Water Using Volumetric Karl Fischer Titration. ASTM International.

  • GB/T 3723 — 工业用化学产品采样安全通则 (Safety code for sampling of chemical products for industrial use). Standardization Administration of China.

  • Globally Harmonized System (GHS) — Classification and Labelling of Chemicals. United Nations Economic Commission for Europe.

  • Regulation (EC) No 1907/2006 (REACH) and Regulation (EC) No 1272/2008 (CLP). European Chemicals Agency.

About the Author

This guide was prepared by the JBSR technical sales team and reviewed by our quality and compliance function. Between them, the two teams handle specification review, certificate checking and pre-shipment inspection for chemical shipments to more than 50 countries, covering acrylic monomers, solvents, glycols, anhydrides and plasticisers.

It reflects working practice rather than a formal standard, and it is not a substitute for the specification agreed with your own supplier. Questions about a specific parameter, or a certificate you are trying to interpret, can be sent to our technical team; the product pages for acrylic acid and styrene list the specifications we publish by default.

Need More Information?

Our experts are ready to help you with your chemical raw material needs